Liefern und montieren von: tML® - FO Trunk Cable 2x MPO Female/2x MPO Female 24G62,5/125µ OM1 LSHF, Type C, Length xxx **tML® - tde Modular Link tML® is a patented, modular cabling system consisting of the three key components module, trunk cable and rack mount enclosure. The system components are 100 percent manufactured, pre-assembled and tested in Germany. They enable plug-and-play installation on site – especially in data centres, but also in industrial environments – within the shortest possible time. Heart of the system are the rear MPO/MTP® and Telco connectors, which can be used to connect at least six or twelve ports at a time. Depending on the module configuration, transfer rates of up to 200G are currently possible with SR4. The fibre optic and TP modules can be used together in a module carrier with a very high port density. The tde offers its tML® cabling system as a proven tML® standard system and in the highly innovative variants tML® Xtended, tML® 24 System and now tML® 32 System for extreme scalability and very easy migration to higher transmission rates such as 40G, 100G, 200G and 400G. **tML® Standard - FO Trunk Cables MPO/MTP® The tML® - FO trunk cable is intended for the connection of two tML®- FO Modules. **TECHNISCHE_DATEN The tML®- FO trunk cable is preterminated with MPO/MTP®connectors on both ends. The end faces of the connectors are optimized by means of Lasercleaving and machine polish. The MPO/MTP®plug has a defined fiber hieght of 1 - 3.5µ. The max. adjacent fiber height difference is 0.2µm and for all fibers 0.3µm. All system components (modules, trunk cables and patch cords) are co-ordinated for the reaching of the performance particularly. The fan-out unit is optimized for tML® - Cable Mounting Bracket for Fan-out Units. The module is marked with sequential serial number and article number. ***FO Connectors The end faces of the connectors are optimized by means of Lasercleaving and machine polish. The MPO/MTP® plug has a defined fiber height of 1 - 3.5µ. The max. adjacent fiber height difference is 0.2µm and for all fibers 0.3µm. Connector: Type MPO/MTP® Female Push Pull Locking (Beige) Ferrule 12 Fiber MM Elite® ferrule, PPS Boot colour Black Temperature range -40°C to +75°C Manufacturer tde/US Conec Optical Performance: Fiber Type Wavelength Insertion loss typ. Insertion loss max. Return loss min. 50/125µ OM2 MPO/MTP® 850 nm ≤ 0.25 dB 0.45 dB 20 dB 62.5/125µ OM1 MPO/MTP® 850 nm ≤ 0.25 dB 0.45 dB   ***FO Fan-Out Fan-out length 50 mm Ø Fan-out 16 mm Ø Single unit 3.8 mm Single unit length 78 ± 5 cm (not stepped) ***FO Cables Standards: ISO 11801 2nd edition EN 187 000 IEC 60794-2 IEC 60794-2-20 EN 50 173-1 IEC 60794-2-21 Construction: Cabletype Universal U-DQ(ZN)BH for indoor and outdoor use Central strength member ø2.5 mm FRP rod Lose tube ø2.3 mm jelly filled loose tubes, with 2 – 12 fibers each, up to 22 tubes in two layers, for lay-up Water blocking The core is water blocked using swellable tape and tread Wrapping Polyester nonwoven Strain Relief Glasroving elements Ripcord Polyester ripcord for easy slitting of the sheath Sheath 1.5 mm blue FireBur®, UV stabilized, EN 50290-2-27 Fire rating: IEC 60332-1-2 Single vertical wire test IEC 60754-1 No halogens IEC 60754-2 No acid matters IEC 61034-2 No dense smoke Heat of combustion: Fiber count; 6 fiber/tube Fiber count; 8 fiber/tube Fiber count; 12 fiber/tube MJ/km KWh/m 6-36 8-48 12-72 2200 0.61 Physical properties: Tensile strength (dynamic) E1 6000 N Tensile strength (permanent) E1 4000 N Compressive strength (crush) E3 3000N Impact E4 25 Nm Torsion E7 5 cycles ± 1 turn Kink E10 The cables do not form a kink when a loop is drawn together to a diameter 12 times the cable nominal diameter Temperature range F1 The cables can bear temperature cycling between -40°C to +70°C.     The cables will operate without any attenuation variation (≤0.05 dB) in the temperature interval -30°C to +60°C.     The cables will operate with a maximum attenuation variation of 0.1 dB/km in the temperature interval -40°C to +70°C. Water penetration F5B No water on free end Mechanical properties: Fiber count; Fiber count; Fiber count; Nominal Nominal Minimum 6 fiber/tube 8 fiber/tube 12 fiber/tube diameter cable weight bending radius 6-36 8-48 12-72 13.0mm 145 kg/km 160mm QS-Managementsystem nach ISO 9001/2008, ISO 14001 und TL 9000 Art.-Nr.: TML-MP/MP62B24Gxxx Hersteller: tde - trans data elektronik GmbH Stück_____________ Einzelpreis__________ Gesamtpreis__________