Liefern und montieren von: Draka - UC900 SS27 Cat.7 S/FTP 4P PUR for industrial applications **UC Industrial cables Especially in difficult industrial conditions electrical reserves are needed to ensure an operation of Industrial Ethernet in each case. The cable must withstand loads as follows: • Chemical substances such as oils, solvents etc. • Permanent movement or vibration such as the use in cable   carriers • Advanced ambient electromagnetic interference • Both the cable and through the cable **TP Cable **TECHNISCHE_DATEN Application Work area and patch cord cable IEEE 802.3: 10Base-T; 100Base-T;1000Base-T; 10GBase-T IEEE 802.5 16 MB; ISDN; TPDDI; ATM Standards EIA/TIA 568A; ISO/IEC 11801 2nd ed.; IEC 61156-6 EN 50173-1; EN 50288-4-2 Flame resistance LSHF (FRNC): IEC 60332-1; IEC 60754-2; IEC 61034 Chemical resistance Oil resistant against Mineral – oil, ASTM – oil The sheath material is tested in Hydraulic oil ARAL VITAM 32, Mobil DTE 13 M, Gear oil ARAL DEGOL BG Plus 320 and Tribol 1710/320. Construction: Type UC900 SS27 Cat.7 S/FTP Conductor Stranded bare copper wire Ø 0.42 mm (AWG 27/7) Insulation Foam Skin Polyethylene, Ø 0.98 mm Twisting 2 cores to the pair Pair screen Al-laminated plastic foil Cable lay up 4 pairs (PiMF) to the core Screen Copper braid, tinned Sheath PUR, red Mechanical properties: Bending radius Without load ≥ 25 mm   With load ≥ 50 mm Temperature range  During operation -35°C to +75°C   During installation  -5°C to +50°C UV resistance of the jacket   according to IEC60068-2-5 material Ozone resistance   according to EN 60811-2-1, clause 8 Smoke density   according to EN 50268-2, IEC61034-1 and 2 Corrosivity   according to EN 50267-1 and 2, IEC 60754-1 and 2 Electrical properties at 20°C ± 5°C: Loop resistance   ≤ 340 Ω/km Resistance unbalance   ≤ 3% Insulation resistance (500 V) ≥ 2000 MΩkm Mutual capacitance at 800 Hz Nom. 43 nF/km Capacitance unbalance (pair/ground) ≤ 1500 pF/km Characteristic impedance (1-100) MHz (100 ± 15) Ω   (100 - 250) MHz (100 ± 18) Ω   (250 - 600) MHz (100 ± 25) Ω Nominal velocity of propagation   ca. 79% Propagation delay   ≤ 427 ns/100m Delay skew   ≤ 12 ns/100m Test voltage (DC, 1 min) core/core and core/screen 1000 V Transfer impedance at 1 MHz 25 mΩ/m   at 10 MHz 15 mΩ/m   at 30 MHz 30 mΩ/m Coupling attenuation   75 dB Electrical Data (nominal) acc. to Cat.7 (at 20°C): F MHZ Attenuation NEXT dB PS- NEXT dB ACR dB/100m ELFEXT PS-ELFEXT Return dB/10m dB/100m dB/100m loss dB 1.0 0.3 90 87 90 80 77 23 4.0 0.6 90 87 89 80 77 24 10.0 1.0 90 87 89 80 77 25 16.0 1.3 90 87 89 76 73 25 20.0 1.4 90 87 89 74 71 25 31.2 1.8 90 87 88 70 67 25 62.5 2.6 90 87 87 64 61 23 100.0 3.2 87 84 84 60 57 21 125.0 3.6 85 82 81 58 55 20 155.5 4.0 84 81 80 56 53 19 175.0 4.3 83 80 79 55 52 19 200.0 4.6 82 79 77 54 51 18 250.0 5.1 81 78 76 52 49 18 300.0 5.6 80 77 74 50 47 17 450.0 6.9 77 74 70 47 44 17 600.0 7.9 75 72 67 44 41 17 750.0 8.7 73 70 64 42 39   900.0 9.7 72 69 62 41 38   1000.0 10.2 71 68 61 40 37   Outerdiameter 5.9 mm Fire load 383 MJ/km   0.106 kWh/m Weight 34 kg/km Copper content 24 Tensile force 100 N QS-Managementsystem nach ISO 9001/2008, ISO 14001 und TL 9000 Art.-Nr.: UC900-SS27-4P-PUR-RT Hersteller: tde - trans data elektronik GmbH Stück_____________ Einzelpreis__________ Gesamtpreis__________