Liefern und montieren von: tBL® - TP Trunk Cable both ends preterminated 10GbE 6xRJ45 length: xx **tBL® - tde Basic Link (TP) tBL® tde Basic Link (TP) is a complete system solution for structured cabling in Cat6A for transfer rates of up to 10GbE in real time. The tBL® - cabling link corresponds to a permanent link in accordance with ISO / IEC 11801 (EN 50173). The RJ45 modules are available in the form factors  Keystone (KS) and Data Center (DC). The compact design of the 6fold RJ45 DC module allows a high packing density of up to 48 RJ45 ports on 1U. The RJ45 module is connected to the tBL® - cable termination block by simply plugging. The slim cable termination block can be easily assembled on the cable by using the tBL® - crimp tool and is suitable for preterminated cables. The modular design of individual RJ45 modules are interchangeable at any time without termination. A cost effective alternative product is the RJ45 keystone module without cable termination block in the tool-less design. The system solution is complemented by an extensive portfolio of carrier systems. These include design-capable data outlets, floor box frames, Consolidation points, DIN rail modules and patch panels in 1/2 and 1U. **TP Trunk Cables The tBL® - TP Trunk Cable is intended for the installation in the tBL® module 0.5U (up to 4). **TECHNISCHE_DATEN tBL® - TP Trunk Cable is preterminated on both ends with modules 6x RJ45 10GbE. A full assembly results in 24x RJ45 ports on 0.5U. Cable S/FTP Round Cable 24x2xAWG 26/1, CAT 7, Pet-Al foil around each pair, 3 layers of screened pairs (2+8+14), LSHF-FR   13.2 mm   55 mm   110 mm Flame resistance LSHF-FR IEC 60332-3-24; IEC 60754-2; IEC 61034 Standards ISO/IEC 11801 2nd Edition; EN 50173-5; EN 50288-4-2 Mounting Snap-In Tests Link Performance Tests, electronic test on short-circuit and Visual Final Inspection; all measured values are electronically archived xx - stands for the cable length in meters (max. length is 60m) ***TP RJ45 Modules System platforms tML®/ tSML   4x tBL® - 6fold Modules can be integrated in a tSML - TP Module.   1x tBL® - 6fold Module can be integrated in a tML® - TP Module. Equipping 6x tBL® RJ45 DC Module Cat.6A  ***TP RJ45 Modules Mechanical properties: Type RJ45 Jack shielded Connector standard IEC 60603-7-5-1 Installation dimension 19.3 x 14.7 mm Mating force ≤30 N Mating cycles (RJ45 side) ≥750 Mating cycles (opposite side) ≥100 Housing material nickel-plated die-cast zinc Insulation components material PC aqua Gold plating in contact area 30 µ" Contacting AWG 27-22 Cable diameter 5-10 mm Environmental requirements: Connection class IP20 Temperature range -40°C to +70°C Electrical properties: Contact resistance ≤20 mΩ Insulation resistance between contacts ≥500 MΩ Dielectric withstanding voltage contact – contact ≥1000 V DC/AC Dielectric withstanding voltage contact – screen ≥1500 V DC/AC Current-carrying capacity at 50°C 1.25 A PoE+ per IEEE 802.3at PoE+ Transmission characteristics: 10 GbE supported Cat.6A ISO/IEC 11801 AM1 and AMD2, Link length: >1 m ***TP Termination Block Construction plastic with insulation displacement connection Gold plating termination block 30 µ" Color transparent white Application Flex cable AWG 26 - AWG 27, alternative AWG 26 Solid Wire   Plug bears small flag-like installation guide with color codes for pin-out according to EIA/TIA 568 A and B. ***TP Cable Construction: Type UC FUTURE COMPACT AWG26/1 Cat.7 S/FTP 24P Conductor Bare copper wire, diamter 0.4 mm (AWG26) Insulation Foam-skin PP, diameter 1.0 mm Twisting 2 insulated wires to the pair Pair screening Pet-Al foil around each pair Stranding 6 (5+1) bundles with 4 foiled pairs blue, orange, green, brown   Coloured tapes are around each bundle Screen Tinned copper braid 85% coverage Sheath LSHF-FR, diameter 13.9 mm Application IEEE 802.3: 10Base-T; 100Base-T; 10GBase-T, ISDN; xDSL IEEE 802.5 16 MB; ISDN; TPDDI; ATM155Mbit/s The conductor diameter is smaller compared to the standard installation cables. This leads to an increased attenuation and therefore the operating distance is reduced (60m instead of 90m installation cable in standard permanent link). Standards IEC 61156-6 work area cable ISO/IEC 11801 2nd ed. EN 50173-5 EN 50288-4-2 Flame resistance PVC IEC 60332-1 LSHF-FR IEC 60332-3-24; IEC 60754-2; IEC 61034 ; EN 50399 Class Dca Mechanical properties: Minimum bending radius Without load ≥ 55 mm   With load ≥ 110 mm Temperature range  During operation -20°C up to +60°C   During installation  10°C up to +40°C Electrical properties at 20°C: Loop resistance   ≤ 280 Ω/km Resistance unbalance   ≤ 2% Test voltage core/core 1000 VDC 1 min   core/screen 1000 VDC 1 min Capacitance 800 Hz Nom. 44 nF/km Capacitance unbalance   ≤ 1600 pF/km Impedance 100 MHz 100 Ω± 5 Ω Nominal velocity of propagation   ca. 76% Insulation resistance 500 V ≥ 2000 MΩkm Transfer impedance at 1 MHz ≤ 5 mΩ /m   at 10 MHz ≤ 5 mΩ /m   at 30 MHz ≤ 10 mΩ /m Electrical Data (nominal) acc. to Cat.7 (at 20°C): F MHZ Atten- uation NEXT dB PS- NEXT dB ELFEXT dB/100m PS- ELFEXT Return loss dB dB/10m dB/100m 1.0 0.3 90 87 80 77 23 4.0 0.6 90 87 80 77 24 10.0 1.0 90 87 80 77 25 16.0 1.3 90 87 76 73 25 20.0 1.4 90 87 74 71 25 31.2 1.8 90 87 70 67 25 62.5 2.6 90 87 64 61 23 100.0 3.2 87 84 60 57 21 125.0 3.6 85 82 58 55 20 155.5 4.0 84 81 56 53 19 175.0 4.3  83 80 55 52 19 200.0 4.6 82 79 54 51 18 250.0 5.1 81 78 52 49 18 300.0 5.6 80 77 50 47 17 450.0 6.9 77 74 47 44 17 600.0 7.9 75 72 44 41 17 Technical Data: Designation J-02YS(ST)CH Type 24x2x0.4PiMF Outer diameter 13.9 mm Fire load 2.171 MJ/km Fire load 0.603 kWh/m Reaction to Fire Dca-s2, d2, a1 Weight 230 kg/km Copper content 115 kg/km Tensile force 500 N QS-Managementsystem nach ISO 9001/2008, ISO 14001 und TL 9000 Art.-Nr.: TBL-M06RJ45-xx Hersteller: tde - trans data elektronik GmbH Stück_____________ Einzelpreis__________ Gesamtpreis__________