Liefern und montieren von: FO Universal Cable 4G50/125µm OM2 1.5kN with non-metallic rodent protection **tde - FO Universal cables This cable can be used for LAN and WAN backbones, telecom access lines, fiber to business and fiber to the building drop connections as well as fiber to the home drop and access connections. With its FireBur® LSHF sheathing this cable is ideal for mixed indoor and outdoor installation. This cable features a high tensile strength and a degree of rodent protection, effective in many cases. It is equally suited for installation in ducts and on trays. The cable is suited for installation in tubes by blowing and flooding. The cable may be used for direct burial with proper sand back filling. **FO Cables Features • Robust, non metallic fibre optic outdoor and indoor cable with stranded loose tubes. • High crush resistance for high transmission reliability. • Easy handling due to cable construction with dry interstices. • Non metallic rodent protection. • The two coloured ripcords are easy to identify and enable the safe opening of the cable sheath. • Flame retardant halogen-free FR/LS0H sheath. Application • LAN backbone, access and riser zone. • Connection cable between the building distributors and/or floor distributors. • Suitable for laying in cable trays, ducts and vertical shafts. • Can also be spliced in all FO distributors and joints. **TECHNISCHE_DATEN Mechanical characteristics: Temperature range Storage -25 to +70°C, IEC 60794-1-22 F1   Pulling in -10 to +50°C   Operation -25 to +60°C Tensile performance IEC 60794-1-21 E1 Crush resistance IEC 60794-1-21 E3 Impact IEC 60794-1-21 E4 Repeated bending IEC 60794-1-21 E6 Torsion IEC 60794-1-21 E7 Bend IEC 60794-1-21 E11 Water penetration IEC 60794-1-22 F5 General characteristics: Sheath colour green, similar to RAL 6016 Zero halogen, no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2 Flame propagation IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2 Flame spread IEC 60332-3-24, EN 50266-2-4, VDE 0482-266-2-4 Smoke density IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2 Reaction to fire (Euroclasses) EN 13501-6: Dca-s2,d1,a1 Cabletype Universal U-DQ(ZN)BH for indoor and outdoor use   non metallic, dry interstices, rodent protection, flame retardant, in accordance with IEC 60332.1 and IEC 60332.3 C Fibertype Corning G50/125 OM2 No. of fibers 4 Loose tube 1 Sheath ø 7.6 mm Weight 68 kg/km Bending radius 115 mm Tensile load 1500 N Crush resistance 3000 N continuous   5000 N short term Fire load 275 kWh/km   990 MJ/km Length tolerances (prefabricated with plugs): Tolerances for lengths up to 40m ± 100 cm Tolerances for lengths up to 100m ± 100 cm Tolerances for lengths from 100m ± 2% QS-Managementsystem nach ISO 9001/2008, ISO 14001 und TL 9000 Art.-Nr.: U-DQ(ZN)BH1x04G50-OM2-7,6-GN-Dca Hersteller: tde - trans data elektronik GmbH Stück_____________ Einzelpreis__________ Gesamtpreis__________